#2193 · Logistics & Manufacturing Tool

Factory Energy Yield Loss Calculator

Estimate how much production energy and energy cost are tied to rejected output. The calculator allocates average process energy across all produced units, then attributes that average share to rejects. It also shows saleable yield and the extra gross output needed to replace the loss. This is a planning estimate, not a substitute for submetered scrap-process data.

Calculator

Production inputs
units
units
kWh
$/kWh

How to use this calculator

  1. Enter each measured value in the unit shown.
  2. Review allowances, rates, or operating assumptions and adjust them to match the job.
  3. Select Calculate to update the main result and supporting figures.
  4. Check the interpretation and verify the result against drawings, meters, production records, or supplier rules.

Formula

Reject rate = rejected units ÷ total units
Allocated energy loss = total kWh × reject rate
Energy cost loss = allocated energy loss × price per kWh

What the result means

The main result estimates embedded process energy associated with rejects using an average-per-unit allocation.

Defects found early may embody less energy than finished rejects; use stage-level metering when available.

Example calculation

At 10,000 total units, 250 rejects, 15,000 kWh, and $0.14/kWh, the reject rate is 2.5%. Allocated energy loss is 375 kWh, costing $52.50.

Tips for better results

  • Use measurements and production totals from the same defined scope.
  • Replace default assumptions with project or facility records.
  • Keep unrounded values through the calculation and round only the final purchasing or reporting figure.
  • Record unusual operating or site conditions beside the result.
  • Recalculate when dimensions, schedule, crew, equipment, or process conditions change.

Frequently asked questions

How does reject rate translate into factory energy loss?

The calculator applies the reject share of output to total process energy.

Does the estimate include energy used to rework parts?

Not separately. Add rework energy to total process energy or measure it as its own process.

What if rejected products use more energy than good products?

Use submetered or stage-weighted data; the average allocation here will understate that difference.

Why are replacement gross units higher than rejected units?

Replacement production is also subject to the entered yield, so more starts may be needed.

Can I enter a zero electricity price?

Yes. Energy loss still calculates, while estimated cost loss becomes zero.

Result guide

ItemHow it is used
Good-unit yieldCalculator input in the displayed unit
Allocated energy lossCalculator input in the displayed unit
Estimated energy cost lossCalculator input in the displayed unit
Replacement gross unitsCalculator input in the displayed unit